Inspection Procedure
HINT:
Start the inspection from step 1 when using the Techstream and start from step 2 when not using the Techstream.
- READ VALUE ON TECHSTREAM (IGNITION SWITCH)
- Connect the Techstream to the DLC3.
- Turn the ignition switch on (IG) and turn the Techstream main switch on.
- Select the items below in the "DATA LIST" and read the display on the Techstream.
BODY:
DATA LISTItem Measurement Item/Display (Range) Normal Condition IG SW Ignition switch on (IG)/ON or OFF ON: Ignition switch on (IG)
OFF: Ignition switch off or on (ACC)ACC SW Ignition switch on (ACC)/ON or OFF ON: Ignition switch on (ACC)
OFF: Ignition switch not on (ACC)OK:
When the ignition switch is operated, the display changes as shown above.
NG: Go to step 2
OK : PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
- INSPECT MULTIPLEX NETWORK BODY ECU (IG - ACC TERMINALS)
- Turn the ignition switch off.
- Disconnect the instrument panel J/B (II) connector.
- Measure the voltage according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Voltage
VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition II-9 - Body ground Ignition switch off Below 1 V II-9 - Body ground Ignition switch on (IG) 10 to 14 V II-3 - Body ground Ignition switch off Below 1 V II-3 - Body ground Ignition switch on (ACC) 10 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR (IG OR ACC CIRCUIT)
OK : PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE