Valve Body Assembly: Inspection
- INSPECT SHIFT SOLENOID VALVE SL1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω - Apply 12V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
MEASUREMENT AND SPECIFIED CONDITIONMeasurement Condition Specified Condition Battery positive (+) with a 21 W bulb → Terminal 1
Battery negative (-) → Terminal 2Valve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE S1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 20°C (68°F) 11 to 15 Ω - Apply 12V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
MEASUREMENT AND SPECIFIED CONDITIONMeasurement Condition Specified Condition Battery positive (+) → Shift solenoid valve S1 connector
Battery negative (-) → Shift solenoid valve S1 bodyValve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE S2
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body 20°C (68°F) 11 to 15 Ω - Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
MEASUREMENT AND SPECIFIED CONDITIONMeasurement Condition Specified Condition Battery positive (+) → Shift solenoid valve S2 connector
Battery negative (-) → Shift solenoid valve S2 bodyValve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE S3
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition Shift solenoid valve S3 connector terminal - Shift solenoid valve S3 body 20°C (68°F) 11 to 15 Ω - Apply 12V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
MEASUREMENT AND SPECIFIED CONDITIONMeasurement Condition Specified Condition Battery positive (+) → Shift solenoid valve S3 connector
Battery negative (-) → Shift solenoid valve S3 bodyValve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE S4
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition Shift solenoid valve S4 connector terminal - Shift solenoid valve S4 body 20°C (68°F) 11 to 15 Ω - Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
MEASUREMENT AND SPECIFIED CONDITIONMeasurement Condition Specified Condition Battery positive (+) → Shift solenoid valve S4 connector
Battery negative (-) → Shift solenoid valve S4 bodyValve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SL2
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω - Apply 12V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
MEASUREMENT AND SPECIFIED CONDITIONMeasurement Condition Specified Condition Battery positive (+) with a 21 W bulb → Terminal 1
Battery negative (-) → Terminal 2Valve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SR
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω - Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
MEASUREMENT AND SPECIFIED CONDITIONMeasurement Condition Specified Condition Battery positive (+) → Shift solenoid valve SR connector
Battery negative (-) → Shift solenoid valve SR bodyValve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SLT
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω - Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
MEASUREMENT AND SPECIFIED CONDITIONMeasurement Condition Specified Condition Battery positive (+) with a 21 W bulb → Terminal 2
Battery negative (-) → Terminal 1Valve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SLU
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω - Apply 12V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
MEASUREMENT AND SPECIFIED CONDITIONMeasurement Condition Specified Condition Battery positive (+) with a 21 W bulb → Terminal 2
Battery negative (-) → Terminal 1Valve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.