Inverter Main Switch: Inspection
- INSPECT INVERTER MAIN SWITCH
- Check the resistance.
- Measure the resistance and check the results in accordance with the value(s) in STANDARD RESISTANCE SPECIFICATIONS TABLE .
Standard resistance (Switch operation)
STANDARD RESISTANCE SPECIFICATIONS TABLETester Connections Conditions Specified Conditions B(4) - E(3) Main switch OFF 10 kΩ or higher B(4) - E(3) Main switch ON Below 1 Ω Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the inverter main switch.
Standard resistance (Indicator light circuit)
STANDARD RESISTANCE SPECIFICATIONSTester Connections Conditions Specified Conditions IND (6) - E (3) Main switch OFF 10 kΩ or higher IND (6) - E (3) Main switch ON 20 to 30 Ω If the result is not as specified, replace the bulb.
Standard resistance (Illumination circuit)
STANDARD RESISTANCE SPECIFICATIONSTester Connections Conditions Specified Conditions ILL+(1) - ILL-(2) Always 20 to 30 Ω If the result is not as specified, replace the bulb.
- Measure the resistance and check the results in accordance with the value(s) in STANDARD RESISTANCE SPECIFICATIONS TABLE .
- Check the resistance.