Inspection Procedure
WARNING: This page is about a different car, the 2007 Toyota Camry Solara. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK DTC
- Turn the ignition switch to the ON position, and wait for at least 10 seconds.
- Check the DTCs (See DIAGNOSIS SYSTEM
).
Result:
A: DTC B1771 and B1795 are output.
B: DTC B1795 is output.
HINT:
Codes other than DTC B1771 and B1795 may be output at this time, but they are not related to this check.
A: Go TO DTC B1771
B: Go to Next Step
- CHECK FUSE
- Check the ECU-B fuse.
Standard resistance: Below 1 Ω
NG: REPLACE FUSE
OK: Go to Next Step
- Check the ECU-B fuse.
- CHECK WIRE HARNESS (SOURCE VOLTAGE)
- Turn the ignition switch to the LOCK position.
- Disconnect the negative (-) terminal cable from the battery.
- Disconnect the connector from the occupant classification ECU.
- Connect the negative (-) terminal cable to the battery.
- Turn the ignition switch to the ON position.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITION CHARTTester connection Condition Specified condition O2-1 (+B) - Body ground Always 10 to 14V O2-7 (IG) - Body ground Ignition switch ON 10 to 14 V - Turn the ignition switch to the LOCK position.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester connection Condition Specified condition O2-3 (GND) - Body ground Always Below 1 Ω
NG: REPAIR OR REPLACE WIRE HARNESS
OK: Go to Next Step
- REPLACE OCCUPANT CLASSIFICATION ECU
- Turn the ignition switch to the LOCK position.
- Disconnect the negative (-) terminal cable from the battery.
- Replace the occupant classification ECU (See ON-VEHICLE INSPECTION
).
HINT:
Perform the inspection using parts from a normal vehicle if possible.
- PERFORM ZERO POINT CALIBRATION
- Connect the negative (-) terminal cable to the battery.
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch to the ON position.
- Using the intelligent tester, perform "Zero point calibration" (See INITIALIZATION
).
OK: The "COMPLETED" is displayed.
- PERFORM SENSITIVITY CHECK
- Using the intelligent tester, perform "Sensitivity check" (See INITIALIZATION
).
Standard: 27 to 33 kg (59.52 to 72.75 lb)
NEXT: END
- Using the intelligent tester, perform "Sensitivity check" (See INITIALIZATION
).