2UZ-FE CHARGING - SERVICE DATA

Battery Standard specific gravity 1.25to1.29at20°C(68°F)
Charging circuit without load Standard amperage 10 A or less
Standard voltage 13.2 to 14.8 V
(when engine speed at 2,000 rpm)
Charging circuit with load Standard amperage 30 A or more
Generator rotor Standard resistance between the slip rings 2.3 to 2.7 Ω at 20°C (68°F)
between the slip ring and rotor 10 kΩ or higher
Standard diameter 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter 14.0 mm (0.551 in.)
Generator brush holder Standard exposed length 10.5 mm (0.413 in.)
Minimum exposed length 4.5 mm (0.177 in.)