Service Data
METER - SERVICE DATA
| SPEEDOMETER (ON-VEHICLE) | |
| USA: | |
| Standard indication (mph) | Allowable range (mph) |
| 20 | 19 to 22 |
| 40 | 39 to 42.5 |
| 60 | 59.5 to 63.5 |
| 80 | 79.5 to 84 |
| 100 | 100 to 105 |
| CANADA: | |
| Standard indication (km/h) | Allowable range (km/h) |
| 20 | 17.5 to 21.5 |
| 40 | 38 to 42 |
| 60 | 58 to 63 |
| 80 | 78 to 84 |
| 100 | 98.5 to 104.5 |
| 120 | 119 to 125 |
| 140 | 139 to 145 |
| 160 | 159 to 167 |
| TACHOMETER (ON-VEHICLE) / DC 13.5 V at 25°C (68°F) | |
| Standard indication | Allowable range |
| 700 | 630 to 770 |
| 1,000 | 900 to 1,100 |
| 2,000 | 1,850 to 2,150 |
| 3,000 | 2,800 to 3,200 |
| 4,000 | 3,800 to 4,200 |
| 5,000 | 4,800 to 5,200 |
| 6,000 | 5,750 to 6,250 |
| ENGINE COOLANT TEMPERATURE SENDER GAUGE | |
| Temperature °C (°F) | Resistance (Ω) |
| -20 (-4) | 13,840 to 16,330 |
| 50 (68) | 2,320 to 2,590 |
| 80 (176) | 310 to 326 |
| 110 (230) | 139.9 to 143.5 |