Combination Meter: Removal
- DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
- REMOVE INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY
- Using a screwdriver, detach the 4 clips, 6 claws and remove the instrument cluster finish panel.
HINT:
Tape the screwdriver tip before use.
- Using a screwdriver, detach the 4 clips, 6 claws and remove the instrument cluster finish panel.
- REMOVE COMBINATION METER ASSEMBLY
- Remove the 2 screws.
- Pull the combination meter as indicated by the arrow in the illustration to detach the 2 clips.
- Disconnect the connector and remove the combination meter.