Inspection Procedure
- CHECK FOR DTC
- Turn the power switch ON (IG), and wait for at least 10 seconds.
- Check the DTCs (see DTC CHECK / CLEAR
).
Result
RESULTResult Proceed to DTC B1795 is output. A DTC B1771 and B1795 are output. B HINT:
DTCs other than DTC B1771 and B1795 may be output at this time, but they are not related to this check.
B: Go to DTC B1771
A: Go to Next Step
- CHECK FUSE (ECU-B)
- Check the ECU-B fuse from the instrument panel junction block.
- Measure the resistance of the fuse.
Standard resistance: Below 1 Ω
NG: REPLACE FUSE
OK: Go to Next Step
- CHECK WIRE HARNESS (SOURCE VOLTAGE)
- Turn the power switch OFF.
- Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
- Disconnect the floor wire No. 2 connector from the occupant classification ECU.
- Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
- Measure the voltage of the wire harness side connector.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Condition Specified Condition O4-1 (+B) - Body ground Always 10 to 14 V O4-7 (IG) - Body ground Power switch ON (IG) 10 to 14 V - Turn the power switch OFF.
- Measure the resistance of the wire harness side connector.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Specified Condition O4-3 (GND) - Body ground Below 1 Ω
NG: REPAIR OR REPLACE WIRE HARNESS
OK: Go to Next Step
- REPLACE OCCUPANT CLASSIFICATION ECU
- Turn the power switch OFF.
- Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
- Replace the occupant classification ECU.
- PERFORM ZERO POINT CALIBRATION
- Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
- Connect the intelligent tester to the DLC3.
- Turn the power switch ON (IG).
- Using the intelligent tester, perform the zero point calibration (see INITIALIZATION
).
OK: COMPLETED is displayed.
- PERFORM SENSITIVITY CHECK
- Using the intelligent tester, perform the sensitivity check (see INITIALIZATION
).
Standard value: 27 to 33 kg (59.52 to 72.75 lb)
NEXT: END
- Using the intelligent tester, perform the sensitivity check (see INITIALIZATION
).