LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2007 >> Prius Base >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning >> Air Conditioning System >> Data List / Active Test

Data List / Active Test

  1. READ DATA LIST 

    HINT:

    Using the intelligent tester's DATA LIST allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the DATA LIST early in troubleshooting is one way to save time.

    1. Connect the intelligent tester (with CAN VIM) to the DLC3.
    2. Turn the power switch ON (IG) and turn the intelligent tester ON.
    3. Read the DATA LIST by following the prompts on the tester.

      Air conditioning amplifier 

      DATA LIST

      Item Measurement Item / Display (Range) Normal Condition Diagnostic Note
      ROOM TEMP Room temperature sensor / min.: -6.5°C (20.3°F)
      max.: 57.25°C (135.05°F)
      Actual room temperature is displayed Open in the circuit: -6.5°C (20.3°F)
      Short in the circuit: 57.25°C (135.05°F)
      AMBI TEMP SENS Ambient temperature sensor / min.: -23.3°C (-9.94°F)
      max.: 65.95°C (150.71°F)
      Actual ambient temperature is displayed Open in the circuit: -23.3°C (- 9.94°F)
      Short: in the circuit: 65.95°C (150.71°F)
      EVAP TEMP Evaporator temperature sensor / min.: -29.7°C (-21.46°F)
      max.: 59.55°C (139.19°F)
      Actual evaporator temperature is displayed Open in the circuit: -29.7°C (- 21.46°F)
      Short in the circuit: 59.55°C (139.19°F)
      SOLAR SENS-P Solar sensor (Passenger side) / min.: 0 max.: 255 Increases as brightness increases Open in the circuit: 0
      Short in the circuit: 255
      COOLANT TEMP Engine coolant temperature / min.: 1.3°C (34.34°F)
      max.: 90.55°C (194.99°F)
      Actual engine coolant temperature is displayed while the engine is warmed up -
      SET TEMP-D Set temperature (Driver side) / min.: 0 max.: 255 The same contents as a setting temperature display part are displayed -
      ESTIMATE TEMP-D Estimated temperature (Driver side) / min.: -358.4°C (-613.12°F)
      max.: 358.4°C (677.12°F)
      Damper is at "MAX. COOL": -358.4°C (-613.12°F)
      Damper is at "MAX. HOT": 358.4°C (677.12°F)
      -
      A/M DAMP POS-P Air mix damper position (Passenger side) / min.: -14%
      max.: 113.5%
      Damper is at "MAX. COOL": -10.0%
      Damper is at "MAX. HOT": 100.0% or 71.0%
      -
      A/O DAMP POS Air outlet damper position / min.: -14% max.: 113.5% Damper is at "FACE": -10.0% Damper is at "FACE/FOOT": 12.0%
      Damper is at "FOOT" (Manual): 33.5% or 69.0%
      Damper is at "FOOT" (Auto): 49.0% or 69.0 %
      Damper is at "FACE/DEF": 69.0% or 95.0%
      Damper is at "DEF": 110.0%
      Open in the circuit: 50.0%
      A/I DAMP POS Air inlet damper position / min.: -14% max.: 113.5% Damper is at "RECIRCULATION": -1.0%
      Damper is at "FRESH": 110.0%
      Damper is at "HALFRECIRCULATION": 20.0 to 102.0%
      Open in the circuit: 50.0%
      A/M DAMP TARG-P Air mix damper target position (Passenger side) /
      min.: -14% max.: 113.5%
      Damper is at "MAX. COOL": - 10.0%
      Damper is at "MAX. HOT": 100.0% or 71.0%
      -
      A/O DAMP TARG Air outlet damper target position / min.: -14% max.: 113.5% Damper is at "FACE": -10.0% Damper is at "FACE/FOOT": 12.0%
      Damper is at "FOOT" (Manual): 33.5% or 69.0%
      Damper is at "FOOT" (Auto): 49.0% or 69.0 %
      Damper is at "FACE/DEF": 69.0% or 95.0%
      Damper is at "DEF": 110.0%
      Open in the circuit: 50.0%
      A/I DAMP TARG Air inlet damper target position / min.: -14% max.: 113.5% Damper is at "RECIRCULATION": -1.0%
      Damper is at "FRESH": 110.0%
      Damper is at "HALFRECIRCULATION": 20.0 to 102.0%
      Open in the circuit: 50.0%
      HAND FREE TEL Handsfree telephone / OFF, ON - -
      BLOWER LEVEL Blower motor speed level / min.: Level 0 max.: 31 Increases in the range between 0 and 31 as the speed increases -
      AMBI TEMP Adjusted ambient temperature / min.: -30.8°C (-23.44°F)
      max.: 50.8°C (123.44°F)
      - -
      SET TEMP SHIFT Shift set temperature / +2C, +1C, NORMAL, -1C, -2C Customized value will be displayed -
      AIR INLET MODE Air inlet mode / AUTO, MANUAL Customized value will be displayed -
      COMPRESSOR MODE Compressor mode / AUTO, MANUAL Customized value will be displayed -
      COMPRS/DEF OPER Compressor/DEF operation mode / LINK, NORMAL Customized value will be displayed -
      FOOT AIR LEAK Foot air leak / ON, OFF Customized value will be displayed -
      AUTO BLOW UP Foot/DEF automatic blower up function / ON, OFF Customized value will be displayed -
      FOOT/DEF MODE Foot/DEF auto mode / ON, OFF Customized value will be displayed -
      AMBIENT TMP SFT Ambient temperature shift / +3C, +2C, +1C, NORMAL, -1C, 2C, 3C Customized value will be displayed -
      DESTINATION Destination/ DOMEST, USA, EUROPE, AUSTRAL, MIDEAST, NO INFO Changes with destinations -
      DESTINATION Destination/ DOMEST, USA, EUROPE, AUSTRAL, MIDEAST, NO INFO Changes with destinations -
      HUMIDITY SENS Humidity sensor / min.: 0% max.: 100% Actual room humidity is displayed -
      COMPRS SPD Compressor speed / min.: 0 rpm max.: 65,535 rpm Displays actual rotation speed in the range between 0 rpm and 7,500 rpm -
      COMPRS TARG SPD Compressor target speed / min.: 0 rpm max.: 65,535 rpm Displays target rotation speed in the range between 0 rpm and 7,500 rpm -
      #CODES Number of trouble codes / min.: 0 max.: 255 Number of DTCs will be displayed -
  2. PERFORM ACTIVE TEST 

    HINT:

    Performing the intelligent tester's ACTIVE TEST allows relays, the VSV, actuators and other items to be operated without removing any parts. Performing the ACTIVE TEST early in troubleshooting is one way to save time. The DATA LIST can be displayed in the ACTIVE TEST.

    It is possible to display the DATA LIST on the intelligent tester during the ACTIVE TEST.

    1. Connect the intelligent tester (with CAN VIM) to the DLC3.
    2. Turn the power switch ON (IG) and turn the intelligent tester ON.
    3. Perform the ACTIVE TEST by following the prompts on the tester.

      Air conditioning amplifier 

      ACTIVE TEST DETAIL

      Item Test Details / Display (Range) Diagnostic Note
      BLOWER MOTOR Blower motor / min.: 0 max.: 31 -
      AIR MIX DAMP-P Air mix damper (Passenger side) / min.: -14% max.: 113.5% -
      A/O MODE DAMP-D Air outlet damper position (Driver side) / min.: -14% max.: 113.5% -
      A/I DAMP-LINEAR Air inlet damper position (linear) / min.: -14% max.: 113.5% -
      COMPRS TARG SPD Compressor target speed / min.: 0 max.: 255 -
      DEFOGGER RLY-R Defogger relay (Rear) / OFF, ON -
      WATER PUMP RLY Water pump / OFF, ON -
      ELECTRICAL FAN Electrical fan / OFF, ON -
      DEFOGGER RLY-R Defogger relay (Rear) / OFF, ON -
      A/C MAG CLUTCH Magnetic Clutch Relay / OFF, ON -
      WATER PUMP RLY Water pump / OFF, ON -
      ELECTRICAL FAN Electrical fan / OFF, ON -