Inspection Procedure
- CHECK MULTIPLEX COMMUNICATION SYSTEM
- Check that the multiplex communication system operates normally.
OK : Multiplex communication system operates normally.
NG : GO TO MULTIPLEX COMMUNICATION SYSTEM
OK : GO TO NEXT STEP
- Check that the multiplex communication system operates normally.
- CHECK OPERATION OF COMBINATION METER
- After replacing the combination meter with a new one, check that the key warning light operates normally.
OK : Key warning light operates normally
NG : REPLACE CERTIFICATION ECU
OK : END
- After replacing the combination meter with a new one, check that the key warning light operates normally.