Personal Light Assembly: Inspection
- INSPECT PERSONAL LIGHT ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE SPECIFICATIONTester connection Switch operation Specified resistance 1 - 3 OFF 10 kΩ or higher - Connect the positive (+) lead from the battery to terminal 1 and the negative (-) lead to terminal 3, then check that the illumination comes on when switch operation is ON position.
- Measure the resistance according to the value(s) in the table below.
- INSPECT PERSONAL LIGHT ASSEMBLY (ELECTRO CHROMIC MIRROR INNER MIRROR)
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE SPECIFICATIONTester connection Switch operation Specified resistance 1 - 6 OFF 10 kΩ or higher - Connect the positive (+) lead from the battery to terminal 1 and the negative (-) lead to terminal 6, then check that the illumination comes on when switch operation is ON position.
- Measure the resistance according to the value(s) in the table below.