LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2007 >> Highlander Base, 2.4 D, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 12 (P112 Hybrid Battery Control) >> Battery Current Sensor >> Inspection

Battery Current Sensor: Inspection

WARNING: This page is about a different car, the 2007 Toyota Prius. However, it is still accessible from the selected car via links, so may be relevant.
  1. INSPECT BATTERY CURRENT SENSOR 
    1. Inspect the resistance.
      1. Measure the resistance between terminals 1 (VIB) and 2 (GIB).

        Standard resistance 

        TERMINALS RESISTANCE SPECIFICATION

        Tester Connection Resistance
        Positive probe to terminal 1 (VIB)
        Negative probe to terminal 2 (GIB)
        3.5 to 4.5 kΩ
        Positive probe to terminal 2 (GIB)
        Negative probe to terminal 1 (VIB)
        5 to 7 kΩ

        If the results are not as specified, replace the battery current sensor.

        Fig 1: Identifying Battery Current Sensor Connectors
        G04473994Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      2. Measure the resistance between terminals 1 (VIB) and 3 (IB).

        Standard resistance 

        TERMINALS RESISTANCE SPECIFICATION

        Tester Connection Resistance
        Positive probe to terminal 1 (VIB)
        Negative probe to terminal 3 (IB)
        3.5 to 4.5 kΩ
        Positive probe to terminal 1 (VIB)
        Negative probe to terminal 3 (IB)
        5 to 7 kΩ

        If the results are not as specified, replace the battery current sensor.

      3. Measure the resistance between terminals 2 (GIB) and 3 (IB).

        Standard resistance: 

        0.2 kΩ or less 

        NOTE: Even if the probes are changed around, the resistance will not vary.

        If the result is not as specified, replace the battery current sensor.