Knock Sensor, Intake Manifold: Inspection
- KNOCK CONTROL SENSOR
- Using an ohmmeter, measure the resistance between the terminals.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance:
120 to 280 kΩ at 20°C (68°F)
If the resistance is not specified, replace the sensor.
- Using an ohmmeter, measure the resistance between the terminals.