EFI Relay: Inspection
- INSPECT EFI RELAY
- Using an ohmmeter, measure the resistance according to the value(s) in STANDARD RESISTANCE TABLE the table below.
Standard resistance
STANDARD RESISTANCE TABLETester Connection Specified Condition 1E-7-1E-12 10 kΩ or higher 1E-7-1E-12 Below 1 Ω (Battery voltage is applied between terminals 1E-9 and 1E-10)
- Using an ohmmeter, measure the resistance according to the value(s) in STANDARD RESISTANCE TABLE the table below.