LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2007 >> Avalon XLS >> Repair and Diagnosis >> Electrical >> Body Electrical >> Power Outlet >> Clock >> Removal

Power Outlet: Clock: Removal

  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL 
    CAUTION: Wait for 90 seconds after disconnecting the cable to prevent the airbag working.
  2. REMOVE INSTRUMENT CLUSTER FINISH PANEL GARNISH NO.1  (See REMOVAL )
  3. REMOVE INSTRUMENT CLUSTER FINISH PANEL GARNISH NO.2  (See REMOVAL )
  4. REMOVE INSTRUMENT PANEL FINISH PLATE (w/o Smart Key System)  (See REMOVAL )
  5. REMOVE INSTRUMENT PANEL SUB-ASSEMBLY  (See REMOVAL )
  6. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY CENTER 
  7. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY  (See REMOVAL )
  8. REMOVE COMBINATION METER ASSEMBLY  (See DISASSEMBLY )
  9. REMOVE CLOCK ASSEMBLY 
  10. REMOVE ACCESSORY METER ASSEMBLY 
    1. Disengage the 4 claws and remove the accessory meter assembly.
      Fig 1: Identifying Accessory Meter Assembly Claws
      G05006531Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002