Inspection Procedure
- READ VALUE ON INTELLIGENT TESTER
- Connect the intelligent tester to the DLC3.
- Turn the engine switch on (IG).
- Following the display on the tester, select "DATA LIST".
SMART KEY (Certification ECU):
SMART KEY FUNCTION REFERENCEItem Measurement Item / Range (Display) Normal Condition Diagnostic Note D TRIGGER SW Lock switch / ON or OFF ON: Lock switch is pushed
OFF: Lock switch is not pushed- P TRIGGER SW Lock switch / ON or OFF ON: Lock switch is pushed
OFF: Lock switch is not pushed- DR TRIGGER Lock switch rear LH / ON or OFF ON: Lock switch is pushed
OFF: Lock switch is not pushed- DP TRIGGER Lock switch rear RH / ON or OFF ON: Lock switch is pushed
OFF: Lock switch is not pushed- OK:
"ON" (lock switch is pressed) appears on the tester screen.
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE .
NG: Go to Next Step
- INSPECT LOCK SWITCH
- Remove the outside handle.
- Disconnect the connectors.
- Measure the resistance according to the value(s) in the table below.
Resistance
RESISTANCE REFERENCE CHARTTester Connection Condition Specified Condition W2-1 (TRG-) - W2-3 (TRG+) Lock switch not pushed → Pushed 10 kΩ or higher → Below 1 Ω V2-1 (TRG-) - V2-3 (TRG+) Y2-1 (TRG-) - Y2-3 (TRG+) X2-1 (TRG-) - X2-3 (TRG+) NG: REPLACE OUTSIDE HANDLE
OK: Go to Next Step
- CHECK WIRE HARNESS (CERTIFICATION ECU - LOCK SWITCH)
- Disconnect the D39 and D40 ECU connectors.
- Measure the resistance according to the value(s) in the table below.
Resistance
RESISTANCE REFERENCE CHARTTester Connection Condition Specified Condition D39-3 (TSW1) - W2-3 (TRG+) Always Below 1 Ω D39-4 (TSW2) - V2-3 (TRG+) Always Below 1 Ω D40-25 (TSW3) - Y2-3 (TRG+) Always Below 1 Ω D40-26 (TSW4) - X2-3 (TRG+) Always Below 1 Ω D39-3 (TSW1) - Body ground Always 10 kΩ or higher D39-4 (TSW2) - Body ground Always 10 kΩ or higher D40-25 (TSW3) - Body ground Always 10 kΩ or higher D40-26 (TSW4) - Body ground Always 10 kΩ or higher NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to Next Step
- CHECK WIRE HARNESS (DOOR OSCILLATOR - LOCK SWITCH)
- Disconnect the door oscillator connector.
- Measure the resistance according to the value(s) in the table below.
Resistance
RESISTANCE REFERENCE CHARTTester Connection Condition Specified Condition W1-9 (TRG-) - W2-1 (TRG-) Always Below 1 Ω V1-9 (TRG-) - V2-1 (TRG-) Always Below 1 Ω Y1-9 (TRG-) - Y2-1 (TRG-) Always Below 1 Ω X1-9 (TRG-) - X2-1 (TRG-) Always Below 1 Ω W1-9 (TRG-) - Body ground Always 10 kΩ or higher V1-9 (TRG-) - Body ground Always 10 kΩ or higher Y1-9 (TRG-) - Body ground Always 10 kΩ or higher X1-9 (TRG-) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR