LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2007 >> Avalon Limited >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Door Lock >> Smart Key System >> Certification ECU Power Source Circuit >> Inspection Procedure

Inspection Procedure

  1. INSPECT CERTIFICATION ECU 
    1. Disconnect the D39 certification ECU connector.
    2. Measure the voltage according to the value(s) in the table below.

      Voltage 

      VOLTAGE REFERENCE CHART

      Tester Connection Condition Specified Condition
      D39-1 (+B1) - Body ground Always 10 to 14 V
      D39-18 (IG) - Body ground Engine switch OFF → ON (IG) Below 1 V → 10 to 14 V
      D39-19 (ACC) - Body ground Engine switch OFF → ON (ACC) Below 1 V → 10 to 14 V
    3. Measure the resistance according to the value(s) in the table below.
      Fig 1: Identifying D39 Certification ECU Connector
      G05006078Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    Resistance 

    RESISTANCE REFERENCE CHART

    Tester Connection Condition Specified Condition
    D39-17 (E) - Body ground Always Below 1 Ω

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN  PROBLEM SYMPTOMS TABLE  .