LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2007 >> 4Runner Limited, 4.7 T, AWD >> Repair and Diagnosis >> General Information >> OEM General Information >> Service Specifications >> 2UZ-FE Starting System >> Service Data

Service Data

2UZ-FE STARTING - SERVICE DATA

Starter (1.4 kW type) Rated voltage and output power 12 V 1.4 kW
No-load characteristics Current 90 A or less at 11.5 V
Brush length Standard 15.5 mm (0.610 in.)
Minimum 10.0 mm (0.394 in.)
Spring installed load Standard 17.6 to 23.5 N (1.8 to 2.4 kgf, 4.0 to 5.3 lbf)
Minimum 11.8 N (1.20 kgf, 2.7 lbf)
Commutator
Diameter Standard 30.0 mm (1.181 in.)
Minimum 29.0 mm (1.142 in.)
Undercut depth Standard 0.6 mm (0.024 in.)
Minimum 0.2 mm (0.008 in.)
Circle runout Maximum 0.05 mm (0.0020 in.)
Starter (2.0 kW type) Rated voltage and output power 12 V 2.0 kW
No-load characteristics Current 100 A or less at 11.5 V
Brush length Standard 15.0 mm (0.591 in.)
Minimum 9.0 mm (0.354 in.)
Spring installed load Standard 21.5 to 27.5 N (2.2 to 2.8 kgf, 4.8 to 6.2 lbf)
Minimum 12.7 N (1.3 kgf, 2.9 lbf)
Commutator
Diameter Standard 35.0 mm (1.378 in.)
Minimum 34.0 mm (1.339 in.)
Undercut depth Standard 0.7 mm (0.028 in.)
Minimum 0.2 mm (0.008 in.)
Circle runout Maximum 0.05 mm (0.0020 in.)
Field frame
Shunt coil resistance at 20°C (68°F) 1.5 to 1.9 Ω