Waveform 6
Igniter IGT signal (from ECM to igniter) and Igniter IGF signal (from igniter to ECM)
IGNITER IGT SIGNAL (FROM ECM TO IGNITER) AND IGNITER IGF SIGNAL (FROM IGNITER TO ECM) WAVEFORM REFERENCE
| ECM Terminal Names | Between IGT (1 to 4) and E1 Between IGF1 and E1 |
| Tester Ranges | 2 V/DIV., 20 msec./DIV. |
| Conditions | Idling |
HINT:
The wavelength becomes shorter as the engine rpm increases.