Terminals Of Ecu
- CHECK TRANSMISSION CONTROL ECU
HINT:
Inspect the connectors from the back side while the connector is connected.
ECU CONNECTOR TERMINAL REFERENCESymbols (Terminal No.) Wiring Color Terminal Description Condition Specified Condition +B (T4-1) - E1 (T4-15) L - W-B Power source Power switch ON (IG) 9 to 14 V E02 (T4-2) - Body ground W-B - Body ground Ground Always Below 1 V E01 (T4-3) - Body ground W-B - Body ground Ground Always Below 1 V RZ1 (T4-4) - E2 (T4-16) L - P Rotation angle sensor signal Power switch ON (IG) 4 to 5.5 V RB (T4-5) - E2 (T4-16) GR - P Rotation angle sensor signal Power switch ON (IG) 4 to 5.5 V RA (T4-6) - E2 (T4-16) LG - P Rotation angle sensor signal Power switch ON (IG) 4 to 5.5 V PCON (T4-7) - E1 (T4-15) LG - W-B Communication bus Power switch ON (IG) Pulse generation
(see wave form 1)PPOS (T4-8) - E1 (T4-15) W - W-B Communication bus Power switch ON (IG) Pulse generation
(see wave form 2)IND (T4-9) - E1 (T4-15) R - W-B P position switch indicator light P position switch ON Below 1 V MWA (T4-10) - E1 (T4-15) W - W-B Parking lock motor Power switch ON (IG) 9 to 14 V MVA (T4-11) - E1 (T4-15) R - W-B Parking lock motor Power switch ON (IG) 9 to 14 V MUA (T4-12) - E1 (T4-15) B - W-B Parking lock motor Power switch ON (IG) 9 to 14 V BATT (T4-13) - E1 (T4-15) L - W-B Power source (RAM) Always 9 to 14 V BMA (T4-14) - E1 (T4-15) B - W-B P CON relay Power switch ON (IG) 9 to 14 V E1 (T4-15) - Body ground W-B - Body ground Ground Always Below 1 V E2 (T4-16) - Body ground P - Body ground Ground Always Below 1 V VC (T4-17) - E2 (T4-16) O - P Power source (Rotation angle sensor) Power switch ON (IG) 4 to 5.5 V MPX2 (T4-18) - E1 (T4-15) B - W-B Multiplex communication Power switch OFF
Power switch ON (IG)Below 1 V
Pulse generationMPX1 (T4-19) - E1 (T4-15) GR - W-B Multiplex communication Power switch OFF
Power switch ON (IG)Below 1 V
Pulse generationSIL (T4-20) - E1 (T4-15) W - W-B Diagnosis tester communication Power switch ON (IG) 8 V or higher - Using an oscilloscope, check the waveform 1.
Waveform 1 (Reference)
WAVEFORM 1 REFERENCEItem Content Symbols (Terminal No.) P CON (T4-7) - E1 (T4-15) Tool setting 5 V/DIV., 20 msec./DIV. Condition Power switch ON (IG) - Using an oscilloscope, check the waveform 2.
Waveform 2 (Reference)
WAVEFORM 2 REFERENCEItem Content Symbols (Terminal No.) PPOS (T4-8) - E1 (T4-15) Tool setting 5 V/DIV., 20 msec./DIV. Condition Power switch ON (IG)
- Using an oscilloscope, check the waveform 1.