2TR-FE 2.7L
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8E | Multiply by 0.001 | V | Response rate deterioration level for bank 1 sensor 1 |
| $01 | $91 | Multiply by 0.004 | mA | A/F sensor current |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $05 | Multiply by 0.001 | Seconds | Rich - Lean switch time |
| $02 | $06 | Multiply by 0.001 | Seconds | Lean - Rich switch time |
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8A | Multiply by 1 | Time | Frequency of sensor switching |
| $02 | $8F | Multiply by 0.0003 | Grams | Maximum oxygen storage capacity |
CATALYST - BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst - Bank 1 |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | kPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | kPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | kPa | Test value for leak detection pump stuck OFF (P2401) |
| $3D | $CD | Multiply by 0.001 | kPa | Test value for leak detection pump stuck ON (P2402) |
| $3D | $CE | Multiply by 0.001 | kPa | Test value for vent valve stuck OFF (P2420) |
| $3D | $CF | Multiply by 0.001 | kPa | Test value for vent valve stuck ON (P2419) |
| $3D | $D0 | Multiply by 0.001 | kPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | kPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | kPa | Test value for purge VSV stuck closed (P0441) |
| $3D | $D5 | Multiply by 0.001 | kPa | Test value for purge VSV stuck open (P0441) |
| $3D | $D7 | Multiply by 0.001 | kPa | Test value for purge flow insufficient (P0441) |
SECONDARY AIR INJECTION (AIR)
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $71 | $E1 | Multiply by 0.01 | Gram per second | Test value of AIR insufficient |
| $71 | $E2 | Multiply by 0.01 | kPa | Test value of AIR pump stuck ON |
| $71 | $E3 | Multiply by 0.01 | kPa | Test value of AIR pump stuck OFF |
| $71 | $E4 | Multiply by 0.01 | kPa | Test value of AIR control valve ON |
| $71 | $E5 | Multiply by 0.01 | kPa | Test value of AIR control valve OFF |
MISFIRE
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycle - Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles - Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycle - Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycles - Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycle - Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycles - Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycle - Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycles - Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycle - Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycles - Total |