2ZZ-GE 1.8L
TID $04 : HO2S HEATER
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.000076 (A) | Maximum HO2S heater current (bank 1 sensor 1) | Malfunction criterion |
| 1 | $02 | Multiply by 0.000076 (A) | Maximum HO2S heater current (bank 1 sensor 2) | Malfunction criterion |
TID $08 : THERMOSTAT
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.625 and subtract 40 (°C) | ECT sensor output when estimated ECT reaches malfunction criterion | Malfunction criterion |
TID $04 : HO2S HEATER
| Test ID | Test Items | Descriptions | Unit Conversions | Units | Standard Values |
|---|---|---|---|---|---|
| $07 | - | Minimum HO2 sensor (sensor 1) voltage | Multiply by 0.005 | Volts | Less than maximum TEST LIMIT |
| $08 | - | Maximum HO2 sensor (sensor 1) voltage | Multiply by 0.005 | Volts | More than minimum TEST LIMIT |
O2S TEST RESULT
| Test ID | Test Items | Descriptions | Unit Conversions | Units | Standard Values |
|---|---|---|---|---|---|
| $38 | - | Average time per cycle of HO2 sensor voltage | Multiply by 0.04096 | Second | Between minimum and maximum TEST LIMIT |
O2S TEST RESULT REFERENCE
| Test ID | Test Item | Unit Conversion | Unit | Standard Value |
|---|---|---|---|---|
| $07 | Minimum HO2 sensor (sensor 1) voltage | Multiply by 0.005 | Volt | Less than maximum TEST LIMIT |
| $08 | Maximum HO2 sensor (sensor 1) voltage | Multiply by 0.005 | Volt | More than minimum TEST LIMIT |
| $31 | Average time for HO2 sensor (sensor 1) output to switch from Lean to Rich | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT |
| $32 | Average time for HO2 sensor (sensor 1) output to switch from Rich to Lean | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT. |
| $37 | Time until HO2 sensor voltage drops to 0.2 V during fuel-cut | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT |
| $39 | Switch time for HO2 sensor voltage to drop from 0.35 V to 0.2 V during fuel-cut | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT |
| $81 | Percentage of monitor time that HO2 sensor (sensor 2) voltage below 0.05V | Multiply by 0.390 | % | Less than TEST LIMIT |
| $84 | Percentage of monitor time that HO2 sensor (sensor 2) voltage 0.7 V or more | Multiply by 0.390 | % | More than TEST LIMIT |
| $85 | Continuous time that HO2 sensor (sensor 2) voltage 0.45 V or more | Multiply by 0.26214 | Second | More than TEST LIMIT |
| $87 | Percentage of monitor time that HO2 sensor (sensor 2) voltage 0.45 V or more | Multiply by 0.390 | % | More than TEST LIMIT |
TID $01: CATALYST-USING FRONT HO2S AND REAR HO2S
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 0 | $01 | Multiply by 0.0078 (no dimension) | Catalyst deterioration level bank 1: Determined by waveform of front HO2S and rear HO2S |
Malfunction criterion |
TID $02: EVAP SYSTEM (KEY-OFF MONITOR)
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit | ||
|---|---|---|---|---|---|---|
| 1 | $01 | Multiplied by 0.0156 subtract 2 (kPa) | Test value for small leak (P0456): Refer to pressure D(1) |
Malfunction criteria (0 kPa) | ||
| 1 | $02 | Multiplied by 0.0156 subtract 2 (kPa) | Test value for gross leak (P0455): Refer to pressure E(1) |
Malfunction criteria (0 kPa) | ||
| 1 | $03 | Multiplied by 0.0156 subtract 2 (kPa) | Test value for vacuum pump stuck OFF (P2401): Refer to pressure A(1) |
Malfunction criteria (0 kPa) | ||
| 1 | $04 | Multiplied by 0.0156 subtract 2 (kPa) | Test value for vacuum pump stuck ON (P2402): Refer to pressure A(1) |
Malfunction criteria (0 kPa) | ||
| 1 | $05 | Multiplied by 0.0156 subtract 2 (kPa) | Test value for vent valve stuck OFF (vent) (P2420): Refer to pressure C(1) |
Malfunction criteria (0 kPa) | ||
| 1 | $06 | Multiplied by 0.0156 subtract 2 (kPa) | Test value for vent valve stuck ON (closed) (P2419): Refer to pressure A(1) |
Malfunction criteria (0 kPa) | ||
| 1 | $07 | Multiplied by 0.0156 subtract 2 (kPa) | Test value for 0.02 inch orifice low flow (P043E): Refer to pressure B(1) |
Malfunction criteria (0 kPa) | ||
| 1 | $08 | Multiplied by 0.0156 subtract 2 (kPa) | Test value for 0.02 inch orifice high flow (P043F): Refer to pressure A(1) |
Malfunction criteria (0 kPa) | ||
| 1 | $11 | Multiplied by 0.0156 subtract 2 (kPa) | Test value for purge VSV stuck close (P0441): Refer to pressure F(1) |
Malfunction criteria (0 kPa) | ||
| 1 | $12 | Multiplied by 0.0156 subtract 2 (kPa) | Test value for purge VSV stuck open (P0441): Refer to pressure E(1) |
Malfunction criteria (0 kPa) | ||
| 1 | $13 | Multiplied by 0.0156 subtract 2 (kPa) | Test value for purge flow (P0441): Refer to pressure G(1) |
Malfunction criteria (0 kPa) | ||
|
||||||