LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2006 >> Matrix Base, 4WD >> Repair and Diagnosis >> Engine Performance >> Mode 6 - 2006 TOYOTA >> Matrix >> 2ZZ-GE 1.8L

2ZZ-GE 1.8L

TID $04 : HO2S HEATER

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.000076 (A) Maximum HO2S heater current (bank 1 sensor 1) Malfunction criterion
1 $02 Multiply by 0.000076 (A) Maximum HO2S heater current (bank 1 sensor 2) Malfunction criterion
TID $08 : THERMOSTAT

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.625 and subtract 40 (°C) ECT sensor output when estimated ECT reaches malfunction criterion Malfunction criterion
TID $04 : HO2S HEATER

Test ID Test Items Descriptions Unit Conversions Units Standard Values
$07 - Minimum HO2 sensor (sensor 1) voltage Multiply by 0.005 Volts Less than maximum TEST LIMIT
$08 - Maximum HO2 sensor (sensor 1) voltage Multiply by 0.005 Volts More than minimum TEST LIMIT
O2S TEST RESULT

Test ID Test Items Descriptions Unit Conversions Units Standard Values
$38 - Average time per cycle of HO2 sensor voltage Multiply by 0.04096 Second Between minimum and maximum TEST LIMIT
O2S TEST RESULT REFERENCE

Test ID Test Item Unit Conversion Unit Standard Value
$07 Minimum HO2 sensor (sensor 1) voltage Multiply by 0.005 Volt Less than maximum TEST LIMIT
$08 Maximum HO2 sensor (sensor 1) voltage Multiply by 0.005 Volt More than minimum TEST LIMIT
$31 Average time for HO2 sensor (sensor 1) output to switch from Lean to Rich Multiply by 0.04096 Second Less than maximum TEST LIMIT
$32 Average time for HO2 sensor (sensor 1) output to switch from Rich to Lean Multiply by 0.04096 Second Less than maximum TEST LIMIT.
$37 Time until HO2 sensor voltage drops to 0.2 V during fuel-cut Multiply by 0.04096 Second Less than maximum TEST LIMIT
$39 Switch time for HO2 sensor voltage to drop from 0.35 V to 0.2 V during fuel-cut Multiply by 0.04096 Second Less than maximum TEST LIMIT
$81 Percentage of monitor time that HO2 sensor (sensor 2) voltage below 0.05V Multiply by 0.390 % Less than TEST LIMIT
$84 Percentage of monitor time that HO2 sensor (sensor 2) voltage 0.7 V or more Multiply by 0.390 % More than TEST LIMIT
$85 Continuous time that HO2 sensor (sensor 2) voltage 0.45 V or more Multiply by 0.26214 Second More than TEST LIMIT
$87 Percentage of monitor time that HO2 sensor (sensor 2) voltage 0.45 V or more Multiply by 0.390 % More than TEST LIMIT
TID $01: CATALYST-USING FRONT HO2S AND REAR HO2S

TLT CID Unit Conversion Description of Test Value Description of Test Limit
0 $01 Multiply by 0.0078 (no dimension) Catalyst deterioration level bank 1:
Determined by waveform of front HO2S and rear HO2S
Malfunction criterion
TID $02: EVAP SYSTEM (KEY-OFF MONITOR)

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiplied by 0.0156 subtract 2 (kPa) Test value for small leak (P0456):
Refer to pressure D(1)
Malfunction criteria (0 kPa)
1 $02 Multiplied by 0.0156 subtract 2 (kPa) Test value for gross leak (P0455):
Refer to pressure E(1)
Malfunction criteria (0 kPa)
1 $03 Multiplied by 0.0156 subtract 2 (kPa) Test value for vacuum pump stuck OFF (P2401):
Refer to pressure A(1)
Malfunction criteria (0 kPa)
1 $04 Multiplied by 0.0156 subtract 2 (kPa) Test value for vacuum pump stuck ON (P2402):
Refer to pressure A(1)
Malfunction criteria (0 kPa)
1 $05 Multiplied by 0.0156 subtract 2 (kPa) Test value for vent valve stuck OFF (vent) (P2420):
Refer to pressure C(1)
Malfunction criteria (0 kPa)
1 $06 Multiplied by 0.0156 subtract 2 (kPa) Test value for vent valve stuck ON (closed) (P2419):
Refer to pressure A(1)
Malfunction criteria (0 kPa)
1 $07 Multiplied by 0.0156 subtract 2 (kPa) Test value for 0.02 inch orifice low flow (P043E):
Refer to pressure B(1)
Malfunction criteria (0 kPa)
1 $08 Multiplied by 0.0156 subtract 2 (kPa) Test value for 0.02 inch orifice high flow (P043F):
Refer to pressure A(1)
Malfunction criteria (0 kPa)
1 $11 Multiplied by 0.0156 subtract 2 (kPa) Test value for purge VSV stuck close (P0441):
Refer to pressure F(1)
Malfunction criteria (0 kPa)
1 $12 Multiplied by 0.0156 subtract 2 (kPa) Test value for purge VSV stuck open (P0441):
Refer to pressure E(1)
Malfunction criteria (0 kPa)
1 $13 Multiplied by 0.0156 subtract 2 (kPa) Test value for purge flow (P0441):
Refer to pressure G(1)
Malfunction criteria (0 kPa)
(1) Pressures A to G are indicated as shown in the following diagram below.
Fig 1: EVAP System (Key-Off Monitor) And Purge Flow Monitor Diagram
G04460861Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002