LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2006 >> Matrix Base, 4WD >> Repair and Diagnosis >> Engine Performance >> Mode 6 - 2006 TOYOTA >> Highlander >> 2AZ-FE 2.4L

2AZ-FE 2.4L

TID $07: A/F SENSOR HEATER

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.00017 (A) Maximum heater current (Bank 1) Malfunction criterion for A/F sensor heater
TID $04: HO2S HEATER

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $02 Multiply by 0.000076 (A) Maximum HO2S heater current (Bank 1 Sensor 2) Malfunction threshold for HO2S heater
TID $08: THERMOSTAT

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.625 and subtract 40 (°C) ECT sensor output when estimated ECT has reached to malfunction criterion Malfunction criteria for thermostat
O2S TEST RESULT

Test ID Test Item Description Unit Conversion Unit Standard Value
$07 MIN HO2S V Minimum HO2S voltage Multiply by 0.005 V Less than malfunction threshold
$08 MAX HO2S V Maximum HO2S voltage Multiply by 0.005 V More than malfunction threshold
$31 Time $31 HO2S switch time from Lean to Rich Multiply by 0.04096 second Less than malfunction threshold
$32 Time $32 HO2S switch time from Rich to Lean Multiply by 0.04096 second Less than malfunction threshold
$37 Time $37 Time that HO2S voltage drops to 0.2 V after fuel-cut begins Multiply by 0.04096 second Less than malfunction threshold
$81 Time $81 Percentage in monitor time when HO2S voltage is lower than 0.05 V Multiply by 0.3906 % Less than malfunction threshold
$84 Time $84 Percentage in monitor time when HO2S voltage is 0.7 V or higher Multiply by 0.3906 % More than malfunction threshold
$85 Time $85 Maximum time while HO2S voltage exceeded 0.45 V continuously Multiply by 0.2621 seconds More than malfunction threshold
$87 Time $87 Percentage in monitor time when HO2S voltage is 0.45 V or higher Multiply by 0.3906 % More than malfunction threshold
TID $01: CATALYST - SENSOR 1 A/F SENSOR, SENSOR 2 HO2S

TLT CID Unit Conversion Description of Test Data Description of Test Limit
0 $01 Multiply by 0.0078 (no dimension) Catalyst deterioration level (bank 1):
Determined by waveforms of A/F sensor and HO2S 2
Malfunction criteria for catalyst deterioration
A/F SENSOR

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$01 $91 Multiply by 0.003 [mA] Air-fuel ratio sensor current or bank 1 sensor 1 Malfunction criterion for low side rationality Malfunction criterion for high side rationality
TID $06: A/F SENSOR

TLT CID Unit Conversion Description of Test Data Description of Test Limit
0 $01 Multiply by 0.000244 (no dimension) Parameter for identify A/F sensor response rate (Bank 1) Malfunction threshold for A/F sensor deterioration
EVAP

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiplied by 0.0156 subtract 2 (kPa) Test value for small leak (P0456):)
Refer to pressure D(1)
Malfunction criteria (0 kPa)
1 $02 Multiplied by 0.0156 subtract 2 (kPa) Test value for gross leak (P0455):
Refer to pressure E(1)
Malfunction criteria (0 kPa)
1 $03 Multiplied by 0.0156 subtract 2 (kPa) Test value for vacuum pump stuck OFF (P2401):
Refer to pressure A(1)
Malfunction criteria (0 kPa)
1 $04 Multiplied by 0.0156 subtract 2 (kPa) Test value for vacuum pump stuck ON (P2402):
Refer to pressure A(1)
Malfunction criteria (0 kPa)
1 $05 Multiplied by 0.0156 subtract 2 (kPa) Test value for vent valve stuck OFF (vent) (P2420):
Refer to pressure C(1)
Malfunction criteria (0 kPa)
1 $06 Multiplied by 0.0156 subtract 2 (kPa) Test value for vent valve stuck ON (closed) (P2419):
Refer to pressure A(1)
Malfunction criteria (0 kPa)
1 $07 Multiplied by 0.0156 subtract 2 (kPa) Test value for 0.02 inch orifice low flow (P043E):
Refer to pressure B(1)
Malfunction criteria (0 kPa)
1 $08 Multiplied by 0.0156 subtract 2 (kPa) Test value for 0.02 inch orifice high flow (P043F):
Refer to pressure A(1)
Malfunction criteria (0 kPa)
1 $11 Multiplied by 0.0156 subtract 2 (kPa) Test value for purge VSV stuck close (P0441):
Refer to pressure F(1)
Malfunction criteria (0 kPa)
1 $12 Multiplied by 0.0156 subtract 2 (kPa) Test value for purge VSV stuck open (P0441):
Refer to pressure E(1)
Malfunction criteria (0 kPa)
1 $13 Multiplied by 0.0156 subtract 2 (kPa) Test value for purge flow (P0441):
Refer to pressure G(1)
Malfunction criteria (0 kPa)
(1) Pressures A to G are indicated as shown in the following diagram below.
Fig 1: EVAP Pressure Graph (Key-Off Monitor And Purge Flow Monitor)
G04424151Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002