Back Power Window System (Double Cab): Inspection
- INSPECT BACK POWER WINDOW SWITCH CONTINUITY SWITCH POSITION AND TESTER CONNECTION SPECIFICATION (1 OF 4)
Switch Position Tester Connection Specified Condition UP 1 - 3, 2 - 6 Continuity OFF 2 - 3, 2 - 6 No continuity DOWN 1 - 6, 2 - 3 Continuity If the continuity is not as specified, replace the switch.
- CHECK BACK WINDOW CONTROL RELAY CIRCUIT
- Disconnect the connector from the relay, and check the connector on the wire harness side, as shown in the table below.
If the result is not as specified, there may be a malfunction on the wire harness side or limit switch.
- Reconnect the connector to the relay, and check the connector on the wire harness side, as shown in the table below.
If the result is not as specified, replace the relay.
- Disconnect the connector from the relay, and check the connector on the wire harness side, as shown in the table below.
- CHECK BACK POWER WINDOW MOTOR PTC THERMISTOR OPERATION
- Disconnect the connector from the window motor.
- Connect the positive (+) lead from the ammeter to terminal 1 of the wire harness side connector and the negative (-) lead to the negative terminal of the battery.
- Connect the positive (+) lead from the battery to terminal 2 of the wire harness side connector, and slide the window to the fully closed position.
- Continue to apply voltage and check that the current changes to less than 1 A in 4 to 90 seconds.
- Disconnect the leads from the terminals.
- Approximately 60 seconds later, connect the positive (+) lead from the battery to terminal 1 and the negative (-) lead to terminal 2, and check that the window begins to moves down.
If operation is not as specified, replace the power back window regulator and motor assembly.
- INSPECT POWER MAIN RELAY CONTINUITY SWITCH POSITION AND TESTER CONNECTION SPECIFICATION (2 OF 4)
Tester Connection Specified Condition 3 - 5 No Continuity 3 - 5 Continuity (When battery voltage is applied to terminals 1 and 2) If the continuity is not as specified, replace the relay.
- INSPECT BACK WINDOW RELAY CONTINUITY SWITCH POSITION AND TESTER CONNECTION SPECIFICATION (3 OF 4)
Tester Connection Specified Condition 3 - 5 No Continuity 3 - 5 Continuity (When battery voltage is applied to terminals 1 and 2) If the continuity is not as specified, replace the relay.
- INSPECT WINDOW LIMIT SWITCH CONTINUITY SWITCH POSITION AND TESTER CONNECTION SPECIFICATION (4 OF 4)
Switch position Tester Connection Specified Condition Lever pushed 1 - 2 No continuity Lever released 1 - 2 Continuity If the continuity is not as specified, replace the power back window regulator and motor assembly.