Typical Malfunction Thresholds
TYPICAL MALFUNCTION THRESHOLDS SPECIFICATION TABLE
| Time until "actual ECT" reaches "Closed Loop ECT" |
2 minutes: Engine start ECT is -8.34°C (17°F) or more 5 minutes: Engine start ECT is - 19.45 to -8.34°C (-3 to 17°F) 20 minutes: Engine start ECT is less than - 19.45°C (-3°F) |