Heated Oxygen Sensor: Inspection
- INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSOR
- Disconnect the oxygen sensor connector.
- Using an ohmmeter, measure the resistance between terminals +B and HT.
Resistance: 11 to 16 Ω at 20° C (68° F)
If the resistance is not as specified, replace the sensor.
Torque: 44 N.m (450 kgf.cm, 32 ft.lbf)
- Reconnect the oxygen sensor connector.
- INSPECT OPERATION OF HEATED OXYGEN SENSOR (See DTC P0037, P0038, P0057, P0058: OXYGEN SENSOR HEATER CONTROL CIRCUIT LOW/HIGH (BANK 1 & 2 SENSOR 2) )