LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2005 >> Sequoia Limited, 4WD >> Repair and Diagnosis >> Electrical >> Starter >> Starting System (Service Specifications) >> Starting System >> Service Data

Service Data

Starting - Service Data

Starter Rated voltage and output power 12V
No-load characteristics Current 100 A or less at 11.5V
rpm 2, 500 rpm or less
Brush length  
  STD 15.0 mm (0.591 in.)
Minimum 9.0 mm (0.354 in.)
Spring installed load  
  STD 21.5 to 27.5 N (2.2 to 2.8 kgf, 4.8 to 6.2 lbf)
Minimum 12.7 N (1.3 kgf, 2.9 lbf)
Commutator  
Diameter STD 35.0 mm (1.378 in.)
Minimum 34.0 mm (1.339 in.)
Undercut depth STD 0.7 mm (0.028 in.)
Minimum 0.2 mm (0.008 in.)
Circle runout Maximum 0.05 mm (0.0020 in.)
Field frame  
Shunt coil resistance at 20°C (68°F) 1.5 to 1.9 Ω
Magnetic switch  
Contact plate for wear Maximum 0.9 mm (0.035 in.)