LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2005 >> Matrix Base, 4WD >> Repair and Diagnosis >> Engine Performance >> Mode 6 - 2005 TOYOTA >> CAMRY >> 2AZ-FE 2.4L

2AZ-FE 2.4L

TID $07 A/F SENSOR HEATER

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.00017 (A) Maximum heater current (Bank 1) Malfunction criterion for A/F sensor heater
TID $04 HO2S HEATER

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $02 Multiply by 0.000076 (A) Maximum HO2S heater current (Bank 1 Sensor 2) Malfunction threshold for HO2S heater
TID $08: Thermostat

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.625 and subtract 40 (°C) ECT sensor output when estimated ECT has reached to malfunction criterion Malfunction criteria thermostat
O2S TEST RESULT

Test ID Test Item Description Unit Conversion Unit Standard Value
$07 MIN HO2S V Minimum HO2S voltage Multiply by 0.005 V Less than malfunction threshold
$08 MAX HO2S V Maximum HO2S voltage Multiply by 0.005 V More than malfunction threshold
$31 Time $31 HO2S switch time from Lean to Rich Multiply by 0.04096 second Less than malfunction threshold
$32 Time $32 HO2S switch time from Rich to Lean Multiply by 0.04096 second Less than malfunction threshold
$37 Time$37 Time that HO2S voltage drops to 0.2 volts after fuel-cut begins Multiply by 0.04096 second Less than malfunction threshold
$81 Time$81 Percentage in monitor time when HO2S voltage is lower than 0.05 volts Multiply by 0.3906 % Less than malfunction threshold
$84 Time$84 Percentage in monitor time when HO2S voltage is 0.7 volts or higher Multiply by 0.3906 % More than malfunction threshold
$85 Time$85 Maximum time while HO2S voltage exceeded 0.45 volts continuously Multiply by 0.2621 seconds More than malfunction threshold
$87 Time$87 Percentage in monitor time when HO2S voltage is 0.45 volts or higher Multiply by 0.3906 % More than malfunction threshold
TID $01 CATALYST - SENSOR 1 A/F SENSOR, SENSOR 2 HO2S

TLT CID Unit Conversion Description of Test Data Description of Test Limit
0 $01 Multiply by 0.0078 (no dimension) Catalyst deterioration level (bank 1): Determined by waveforms of A/F sensor and HO2S 2 Malfunction criteria for catalyst deterioration
TID $02 EVAP SYSTEM - LEV II VACUUM MONITOR

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.183 (mmHg) Test value of EVAP VSV stuck close: Determined by fuel tank pressure change during vacuum introduction Malfunction criteria for EVAP VSV stuck closed
0 $02 Multiply by 0.0655 (seconds) Test value of EVAP VSV stuck open: Determined by duration that fuel tank pressure is higher than criteria Malfunction criteria for EVAP VSV stuck open
0 $03 Multiply by 0.0655 (seconds) Test value of canister closed valve (CCV): Determined by duration that fuel tank pressure is lower than criteria Malfunction criteria for Canister Closed Valve (CCV)
0 $04 Multiply by 0.0458 (mmHg) Test value 0.04 inch leak: Determined by fuel tank pressure change Malfunction criteria for 0.04 inch leak
0 $05 Multiply by 0.0458 (mmHg) Test value 0.02 inch leak: Determined by fuel tank pressure change Malfunction criteria for 0.02 inch leak
TID $06 A/F SENSOR

TLT CID Unit Conversion Description of Test Data Description of Test Limit
0 $01 Multiply by 0.000244 (no dimension) Parameter for identify A/F sensor response rate (Bank 1) Malfunction threshold for A/F sensor deterioration