Typical Enabling Conditions
TYPICAL ENABLING CONDITIONS SPECIFICATION TABLE
| The monitor will run whenever the following DTCs are not present | See "List of Disable a Monitor" (in PRE-CHECK ) |
Output Voltage:
OUTPUT VOLTAGE SPECIFICATION TABLE
| Time for which the following conditions, A & B, are met | 290 seconds or more (coolant temp. < 75°C) 193 seconds or more (coolant temp. ge 75°C) |
| A. Fuel system status | Closed-loop |
| B. Idling | OFF |
| Deceleration count (number of acceleration and deceleration times) | 30 times |
| Deceleration is counted up when vehicle decelerates | More than 3 mph (5 km/h)/2 seconds |
Sensor Element:
SENSOR ELEMENT SPECIFICATION TABLE
| Vehicle speed | 2 mph (3 km/h) or more |
| Idling | OFF |
| Fuel-cut | OFF |
| Time after fuel-cut ON to OFF | 10 seconds or more |
| Intake air volume per engine revolution | 0.19 g/rev or more |
Response:
RESPONSE SPECIFICATION TABLE
| HO2 sensor (sensor 2) voltage before the fuel cut | 0.2 V or more |
| Catalyst condition | Warmed up |
| Engine coolant temperature | 70°C (158°F) or more |
| Fuel-cut | Operating |