Service Data
2AZ-FE
Emission Control System Service Data Specifications Chart (2AZ-FE)
| A/F sensor(bank 1 sensor 1) resistance | at 20°C (68°F) | 0.8 to 1.4 Ω |
| at 800°C (1,472°F) | 1.8 to 3.2 Ω | |
| Oxygen sensor (bank 1 sensor 2) resistance | at 20°C (68°F) | 11 to 16 Ω |
| at 800°C (1,472°F) | 23 to 32 Ω | |
| VSV for EVAP resistance | at 20°C (68°F) | 26 to 30 Ω |
3MZ-FE
Emission Control System Service Data Specifications Chart (3MZ-FE)
| A/F sensor (bank 1 sensor 1) resistance | at 20°C (68°F) | 0.8 to 1.4 Ω |
| at 800°C (1,472°F) | 1.8 to 3.2 Ω | |
| A/F sensor(bank 2 sensor 1) resistance | at 20°C (68°F) | 0.8 to 1.4 Ω |
| at 800°C (1,472°F) | 1.8 to 3.2 Ω | |
| Oxygen sensor (bank 1 sensor 2) resistance | at 20°C (68°F) | 11 to 16 Ω |
| at 800°C (1,472°F) | 23 to 32 Ω | |
| Oxygen sensor (bank 2 sensor 2) resistance | at 20°C (68°F) | 11 to 16 Ω |
| at 800°C (1,472°F) | 23 to 32 Ω | |
| VSV for CCV resistance | at 20°C (68°F) | 25 to 30 Ω |
| at 100°C (212°F) | 32 to 40 Ω | |
| VSV for EVAP resistance | at 20°C (68°F) | 26 to 30 Ω |