Service Data

Charging Service Data List

Battery Voltage at 20°C (68°F) 12.7 -- 12.9 V
Specific gravity at 20°C (68°F) 1.25 -- 1.29
Generator Rated output 12 V 80 A
Rotor coil resistance M/T 2.7 -- 3.1 Ω
A/T 2.1 -- 2.5 Ω
Slip ring diameter STD 14.2 -- 14.4 mm (0.559 -- 0.567 in.)
Minimum 12.8 mm (0.504 in.)
Brush exposed length STD 10.5 mm (0.413 in.)
Minimum 1.5 mm (0.059 in.)
Voltage regulator Regulating voltage 13.2 -- 14.8 V