Inspection Procedure
- INSPECT POWER SOURCE CONTROL ECU
- Disconnect the D44 switch connector.
- Measure the resistance according to the value(s) in POWER SOURCE CONTROL ECU
.
Standard:
POWER SOURCE CONTROL ECUTester Connection (Symbols) Condition Specified condition D44-6 (GND2) - Body ground Always Below 1 Ω
- NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
- OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (SEE PROBLEM SYMPTOMS TABLE )