Starter Service Data

Starter      
Rated voltage and output power   12 V
No-load characteristics Current 100 A or less at 11.5V
  rpm 2,500 rpm or less
Brush length    
  STD 15.0 mm (0.591 in.)
  Minimum 9.0 mm (0.354 in.)
Spring installed load    
  STD 21.5 - 27.5 N (2.2 - 2.8 kgf, 4.8 - 6.2 lbf)
  Minimum 12.7 N (1.3 kgf, 2.9 lbf)
Commutator    
Diameter STD 35.0 mm (1.378 in.)
  Minimum 34.0 mm (1.339 in.)
Undercut depth STD 0.7 mm (0.028 in.)
  Minimum 0.2 mm (0.008 in.)
Circle runout Maximum 0.05 mm (0.0020 in.)
Field frame    
Shunt coil resistance at 20°C (68°F) 1.5 - 1.9 Ω
Magnetic switch    
Contact plate for wear Maximum 0.9 mm (0.035 in.)