Terminals Of Ecu
- TRANSMISSION CONTROL ECU ASSY
HINT:
Inspect the connectors from the back side while the connector is connected.
ECU TERMINALS CONDITION
| Terminal No. (Symbols) | Wiring color | Terminal description | Condition | Specified value |
|---|---|---|---|---|
| T4-1 - T4-15 (+B - E1) | L - W-B | Power source | Power switch on (IG) | 9 to 14 V |
| T4-2 (E02) - Body ground | W-B - Body ground | Ground | Always | Below 1 V |
| T4-3 (E01) - Body ground | W-B - Body ground | Ground | Always | Below 1 V |
| T4-4 -T4-16 (RZ1 - E2) | L - P | Rotation angle sensor signal | Power switch on (IG) | 4 to 5.5 V |
| T4-5 - T4-16 (RB - E2) | GR - P | Rotation angle sensor signal | Power switch on (IG) | 4 to 5.5 V |
| T4-6 - T4-16 (RA - E2) | LG - P | Rotation angle sensor signal | Power switch on (IG) | 4 to 5.5 V |
| T4-7 -T4-15 (PCON - E1) | LG - W-B | Communication Bus | Power switch on (IG) | Pulse generation(see waveform 1) |
| T4-8 - T4-15 (PPOS - E1) | W - W-B | Communication Bus | Power switch on (IG) | Pulse generation (see wave form 2) |
| T4-9 - T4-15 (IND - E1) | R - W-B | P position switch indicator light | P position switch on | Below 1 V |
| T4-10 - T4-15 (MWA - E1) | W - W-B | Parking lock motor | Power switch on (IG) | 9 to 14 V |
| T4-11 - T4-15 (MVA - E1) | R - W-B | Parking lock motor | Power switch on (IG) | 9 to 14 V |
| T4-12 - T4-15 (MUA - E1) | B - W-B | Parking lock motor | Power switch on (IG) | 9 to 14 V |
| T4-13 - T4-15 (BATT - E1) | L - W-B | Power source (RAM) | Always | 9 to 14 V |
| T4-14 - T4-15 (BMA - E1) | B - W-B | P CON relay | Power switch on (IG) | 9 to 14 V |
| T4-15 (E1) - Body ground | W-B - Body ground | Ground | Always | Below 1 V |
| T4-16 (E2) - Body ground | P - Body ground | Ground | Always | Below 1 V |
| T4-17 - T4-16 (VC - E2) | O - P | Power source(Rotation angle sensor) | Power switch on (IG) | 4.5 to 5.5 V |
| T4-18 - T4-15 (MPX2 - E1) | B - W-B | Multiplex communication | Power switch off Power switch on (IG) | Below 1 V Pulse generation |
| T4-19 - T4-15 (MPX1 - E1) | GR - W-B | Multiplex communication | Power switch off Power switch on (IG) | Below 1 V Pulse generation |
| T4-20 -T4-15 (SIL - E1) | W - W-B | Diagnosis tester communication | Power switch on (IG) | 8 V or higher |
- Wave form 1WAVE FORM 1
Item Content Measure terminal PCON - E1 Measure set 5V/DIV, 20 ms/DIV Condition Power switch on (IG) - Wave form 2
WAVE FORM 2
| Item | Content |
|---|---|
| Measure terminal | PPOS - E1 |
| Measure set | 5V/DIV, 20 ms/DIV |
| Condition | Power switch on (IG) |