LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2004 >> Matrix Base, FWD, Standard >> Repair and Diagnosis >> Engine Performance >> Mode 6 - 2004 TOYOTA >> TACOMA >> 5VZ-FE 3.4L

5VZ-FE 3.4L

TID $07: A/F Sensor Heater

Test ID/Comp ID Description of Test Data Description of Test Limit Conversion Factor (Unit)
$07/$81 Maximum A/F sensor heater current Maximum threshold heater current to detect A/F sensor heater circuit malfunction Multiply by 0.173 (A)
$07/$90 Maximum A/F sensor heater current Maximum threshold heater current to detect A/F sensor heater circuit malfunction Multiply by 0.173 (A)
O2S Heater

Test ID/ Comp ID Description of Test Data Description of Test Limit Conversation
Factor (Unit)
$02 Multiply by 0.000076 (A) Maximum HO2S heater current (bank 1 sensor 2) Malfunction criterion
THERMOSTAT

Test ID/ Comp ID Description of Test Data Description of Test Limit Conversion Factor
$08/$81 Difference between actual and estimated engine coolant temperature is 75 °C (167 °F) Malfunction criteria for thermostat Multiply by 0.625 and minus 40 (Degree C)
HO2S Output Voltage (Rich or Lean Stuck)

Test ID Description of TEST DATA Standard Value of TEST LIMIT Conversion Factor (Unit)
$07 The minimum sensor voltage while the malfunction is being monitored Within 0.4 V -
$08 The maximum sensor voltage while the malfunction is being monitored 0.6 V or more -
HO2S Output Voltage (Stuck Low)

Test ID Description of TEST DATA Standard Value of TEST LIMIT Conversion Factor (Unit)
$81 Percentage of monitoring time where heated oxygen sensor voltage is less than 0.05 V Within 60 % Multiply by 0.3906 (%)
$84 Percentage of monitoring time where heated oxygen sensor voltage is 0.70 V or more 20 % or more Multiply by 0.3906 (%)
$85 Maximum Rich (0.45 V or more) time 20 seconds or more Multiply by 0.2621 (sec)
CATALYST

Test ID/Comp ID Description of Test Data Conversion Factor Unit Description of Test Limit
$01/$01 Catalyst deterioration (bank 1) level determined by waveforms of the A/F sensor and heated oxygen sensor Multiply by 0.007812 (no dimension) N/A Malfunction criteria for catalyst deterioration