Inspection Procedure
- Check SMT warning light.
Refer to the troubleshooting for the combination meter in INSPECTION .
- NG: Replace bulb or repair combination meter assembly.
- OK: Go to next step
- Check for short in connectors and wire harness between combination meter and ECM ( PROCEDURE
).
- NG: Repair or replace wire harness and connector.
- OK: Go to next step
- Check ECM power source circuit ( ECM Power Source Circuit
).
- NG: Replace ECM.
- OK: Go to next step
- Check for short in connectors and wire harness between ECM and transmission control ECU ( PROCEDURE
).
- NG: Repair or replace wire harness and connector.
- OK: Replace transmission control ECU ( PROCEDURE ).