Inspection Procedure
HINT:
Troubleshoot each trouble symptom in accordance with the chart below.
| MIL remains on | Start inspection from step 1 |
| MIL is not illuminated | Start inspection from step 3 |
- Clear DTC.
PREPARATION:
- Connect the hand-held tester or the OBD II scan tool to the DLC 3.
- Turn the ignition switch ON and push the hand-held tester or the OBD II scan tool main switch ON.
- Read the DTC (See PRE-CHECK ).
- Clear the DTC (See PRE-CHECK ).
CHECK:
Check that MIL is not illuminated.
Standard: MIL is not illuminated
OK: Repair circuit indicated by output code (See DIAGNOSTIC TROUBLE CODE CHART ).
NG: Go to next step.
- Check harness and connector (Check for short in wire harness).
PREPARATION:
- Disconnect the E4 ECM connector.
- Turn the ignition switch ON.
CHECK:
Check that MIL is not illuminated.
Standard: MIL is not illuminated
OK: Replace ECM (See COMPONENTS ).
NG: Check and repair harness and connector (Combination meter - ECM).
- Check that MIL is illuminated.
CHECK:
Check that MIL is illuminated when turning the ignition switch ON.
Standard: MIL is illuminated
OK: System OK.
NG: Go to next step.
- Inspect combination meter (MIL circuit).
See the TROUBLESHOOTING ).
NG: Repair or replace bulb or combination meter.
OK: Check and repair harness and connector (Combination meter - ECM).