LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2004 >> Celica GT, Standard >> Repair and Diagnosis >> Quick Lookups >> Common Specs & Procedures >> Charging System >> Generator >> Service Specifications

Service Specifications

GENERATOR SERVICE SPECIFICATIONS

Application Specification
Rated Output 12 Volts/80 Amps
Rotor Coil resistance @ 68°F (20°C)
A/T 2.1-2.5 Ohms
M/T 2.7-3.1 Ohms
Slip Ring Diameter
Standard .559-0.567 in. (14.2-14.4 mm)
Minimum .504 in. (12.8 mm)
Brush Exposed Length
Standard .413 in. (10.5 mm)
Minimum .059 in. (1.5 mm)
GENERATOR SERVICE SPECIFICATIONS (VOLTAGE REGULATOR)

Application Specification
Regulating Voltage 13.2-14.8 Volts