Service Data
Emission Control Service Data (2AZ-FE)
| VSV for Canister closed valve | ||
| Resistance | at 20°C (68°F) | 25 to 30 Ω |
| at 100°C (212°F) | 32 to 42 Ω | |
| Air fuel ratio sensor (Bank 1 Sensor 1) | ||
| Resistance | 1 (HT) - 2 (+B) | 2.16 to 2.90 Ω at 20°C (68°F) |
| 1 (HT) - 4 (AF-) | No continuity | |
| Heated oxygen sensor (Bank 1 Sensor 2, 3) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16Ω at 20°C (68°F) |
| 1 (HT) - 4 (E1) | No continuity |
Emission Control Service Data (1MZ-FE)
| Heated oxygen sensor (Bank 1 Sensor 2) | ||
| Resistance | 1 (HT) - 2 (+B) 1 | 11 to 16Ω at 20°C (68°F) |
| (HT) - 4 (E1) | No continuity |