Magnetic Switch: V6

  1. Check whether the pull-in coil has an open circuit. Using an ohmmeter, check that there is continuity between terminals No. 50 and "C". See Fig 1. If there is no continuity, check and replace the magnetic switch.
  2. Check whether the pull-in coil has an open circuit. Using an ohmmeter, check that there is continuity between terminal No. 50 and the switch body. If there is no continuity, check and replace the magnetic switch.
Fig 1: Testing Magnetic Switch (V6 Models)
G00297807Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002