LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2002 >> RAV4 Base, AWD, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 249 (HVAC - General Servicing) >> Water Valve >> Installation

Water Valve: Installation

WARNING: This page is about a different car, the 2002 Toyota Sequoia. However, it is still accessible from the selected car via links, so may be relevant.

Installation is in the reverse order of removal  . See REMOVAL .

  1. After installation, check water valve operation  :
    1. Turn ignition switch to ON.
    2. Operate temperature control switches to "MAX. COOL" and "MAX. WARM", then check that water valve operation, as shown in the illustration. See Figure.

    If operation is not as specified, go to step  2.

  2. Adjust water valve control cable  :
    1. Disconnect the control cable.
    2. Turn ignition switch to ON.
    3. Set temperature control switches "MAX. COOL".
    4. NOTE: Lock the clamp while lightly pushing the outer cable in the direction, as shown in the illustration by an arrow. See Fig 1.
    5. Set the water valve lever on "COOL" position, connect the control cable and lock the clamp.
    Fig 1: Adjusting Water Valve Control Cable
    G01127883Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002