Land Cruiser
- Connect negative lead from battery to door lock actuator terminal No. 2. Connect positive lead from ammeter to door lock actuator terminal No. 3 and negative ammeter lead to positive battery terminal. See Figure. Current should change from 3.2 amps to less than 0.5 amps within 20-70 seconds.
- Wait approximately 60 seconds and connect positive lead from battery to terminal No. 2 and negative lead to terminal No. 3. Door lock actuator should move to LOCK position. If operation is not as specified, replace door lock actuator assembly.