Code P0133 - Heated Oxygen Sensor (Right Side) Circuit Slow Response: Condition
Code is set when ECM detects a response time of one second or more from sensor to change from rich to lean, or lean to rich. Possible cause is heated oxygen sensor.
NOTE:
Oxygen sensor located nearest radiator is referred to as left oxygen sensor. See Figure.