Service Precautions
When working with FIPG material, you must be observe the following precautions:
- Using a razor blade and gasket scraper, remove all the old (FIPG) material from the gasket surfaces.
- Thoroughly clean all components to remove all the loose material.
- Clean both sealing surfaces with a non-residue solvent.
- Apply the sealant in about 0.04 in. (1 mm) bead along the sealing surface.
- Parts must be assembled within 10 minutes of application. Otherwise, the sealant (FIPG) material must be removed and reapplied.