Pick-Up Coil Air Gap
Using a flat, non-magnetic feeler gauge, check air gap between signal rotor and pick-up coil projection. See Fig 1 or Fig 2. Air gap should be .008-.016" (.20-.40 mm). Pick-up coil is not adjustable. Pick-up coil and breaker plate must be replaced.