Rough Engine Operation
Check vacuum hose between vacuum solenoid valve (if equipped) and intake manifold for damage or loose connections. Check for malfunctions in all valves. Ensure all vacuum hoses are tight and in good condition.
BI-METALLIC VACUUM SWITCHING VALVE (BVSV)
- Drain engine coolant. Remove BVSV. Connect hose to top port. Place valve in water that is less than 95°F (35°C). Blow air into hose. Ensure valve is closed.
- Heat water to 129°F (54°C). Blow air into hose. Ensure valve is open. If valve is not open, replace valve. Apply liquid sealer to threads of valve before installing. Refill engine with coolant. If BVSV does not operate as described, replace valve.