Automatic Choke
- Set coil housing scale to center line of thermostat case. Turn coil housing and adjust engine starting mixture to conform with vehicle operating conditions.
- When starting mixture is too rich, turn clockwise; when too lean, turn counterclockwise. Choke valve fully closes at atmospheric temperature of 86°F (30°C).