- Turn ignition switch on. Connect negative voltmeter lead to a good ground and positive lead to ignition coil positive terminal. Voltage reading should be 12 volts.
- Next, connect voltmeter positive lead to ignition coil negative terminal, with negative lead still connected to ground. Voltage should still be 12 volts.
- Unplug wiring connector from distributor. Using a 1.5 volt dry cell battery, connect battery positive pole to Pink wire terminal and negative pole to White wire terminal. Do NOT apply voltage for more than 5 seconds. Voltage at negative terminal of ignition coil should now read 5 volts less than battery voltage. If not, replace ignitor.