Fluid Coupling (90 Degrees) - Front Drive Unit - Remove And Replace: Remove
- Remove the front subframe. See SUBFRAME ASSEMBLY - FRONT (DUAL MOTOR) - REMOVE AND INSTALL .
- Position the fluid catcher under the subframe and fixture assembly.
- Release the front drive unit inverter inlet hose from the 90 degree fluid coupling.
- Remove the bolts (x3) that attach the LH motor mount to the front drive unit, and then remove the mount from the front drive unit.
35 Nm (25.8 lbs-ft) 55 degrees
- E14 socket
Tip: Use of the following tool(s) is recommended:
- Remove the screw that attaches the front drive unit 90 degree fluid coupling to the drive inverter.
6 Nm (4.4 lbs-ft)
- T25 socket
Tip: Use of the following tool(s) is recommended:
- Remove the 90 degree fluid coupling from the drive inverter and discard it.