Rear Drive Unit Assembly - Assembly, Cover, Phase Out, 3DU - Remove And Replace: Notes
Last modified: 23/05/2024 06:50:51
NOTE:
See PERSONAL PROTECTION
to make sure wearing proper PPE when performing the below procedure.
- 1450875-00-A Kit, Inverter Leak Test Adapter, M3
- 1140501-00-A Pack Kit, Enclosure, Leak Test, HV Battery, Complete
- 1140311-00-A Lever Lock, HV Connector, Model 3
WARNING:
Only technicians who have been trained in High Voltage Awareness
and have completed all required certification courses (if applicable) are permitted to perform this procedure. Proper personal protective equipment (PPE)
and insulating HV gloves
with a minimum rating of class 0
(1000V) must be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003
, "High Voltage Awareness Care Points" for additional safety information.